Hioki 3196 Power Quality Analyzer

Hioki 3196 Power Quality Analyzer

Model: Hioki 3196

Manufactured By: HIOKI

Catalogue: Hioki 3196.pdf

Description: Monitor and record the quality of power to analyze the cause of trouble when it occurs! The 3196 is your most reliable and complete instrument for power quality troubleshooting!

FEATURES:

Measure power factor
Sags
Swells
Flicker
Transients
Harmonics to the 50th
High Frequency transient
Detection and waveform display
Four current and Four voltage channels
SPECIFICATIONS:

Measurement lines Single-phase/two-wires, Single-phase/three-wires, Three-phase/three-wires, Three-phase/four-wires
Measurement items Impulsive voltage quality:Transient overvoltage (Impulse), RMS voltage quality:Voltage swell, Voltage dips, Voltage interruption, Power quality:Frequency, Voltage, Current, Current peak, Active/Reactive/Apparent power, Power factor (displaced power factor), Three phase quality:Voltage unbalance ratio, Current unbalance ratio, Harmonic quality (Up to 50th order):Harmonic voltage, Harmonic current, Harmonic power, Inter-harmonic voltage, Inter-harmonic current, Harmonic voltage current phase angle, Total harmonic voltage distortion, Total inter-harmonic current distortion (THD-F, THD-R), Total inter-harmonic voltage distortion ratio, Total inter-harmonic current distortion ratio (THD-F, THD-R), K factor, Flicker:Measures delta- V10 flicker (Japanese domestic), or IEC flicker [Pst, Plt] (international standards),
Measurement ranges Voltage ch1 to ch3: 150.00 to 600.00 V AC rms-3 ranges, ch4: 60.000 to 600.00 V AC rms-4 ranges, or 60.000/600.00 V DC-2 ranges, Current (When using 100 A sensor): 50.000/100.00 A AC rms-2 ranges, Current (When using 500 A sensor): 50.000/500.00 A AC rms-2 ranges, Current (When using FLEXIBLE CLAMP ON SENSOR 9667): 500.00 A / 5000.0 A AC rms-2 ranges, Current (When using CLAMP ON SENSOR 9669): 1000.0A AC rms-1 range, Current (When using CLAMP ON SENSOR 9694): 5.0000A / 50.000 A AC rms-2 ranges, Power: Combination pattern of voltage and current ranges
Measurement method Transient overvoltage: 2 mega-sampling/sec, Harmonic wave: 2048 point (10 cycle at 50 Hz, or 12 cycle at 60 Hz), Other effective value: 256 point/one cycle
Memory capacity 13 MB
Interface PC card slot (9726/ 9727/ 9728 PC card, 128MB to 512MB), RS-232C, LAN (10BASE-T)
Power supply 12 V DC output AC ADAPTER 9458 (Universal 100 to 240 V AC, 50/60 Hz), or BATTERY PACK 9459 (7.2 V/2450 m Ah Ni-MH)
Dimensions, mass 298 mm(11.73 in)W 215 mm(8.46 in)H 67 mm(2.64 in)D, 2.25 kg (79.4 oz)...within battery
Accessories Voltage cord (one set), AC ADAPTER 9458 (1), BATTERY PACK 9459 (1), shoulder strap (1), LAN connector cover (1), marking label (1), Down96 (data download software)